SDR Engineers is a Queensland structural and civil engineering consultancy. We are Registered Professional Engineers of Queensland (RPEQ). We help homeowners, builders, building certifiers, body corporates and services contractors with retaining walls, Form 15 and Form 12 certification, small structural works, waterproofing, leak investigations, concrete repairs and seismic restraint design.
We work across South-East Queensland, including Brisbane, Ipswich, Logan, Moreton Bay, the Gold Coast and the Sunshine Coast. Many design and certification jobs can be done anywhere in Queensland from plans and photos, so get in touch even if you are outside these areas.
Send us your plans, photos and site address through the Request a quote form, by email to info@sdrengineers.com.au, or call 0431 589 914. A few phone photos and rough measurements are often enough for us to give a fixed-price quote.
We usually reply within one business day. Typical turnaround once you accept the quote is 3-5 business days for design and certification. Urgent jobs can often be prioritised, so just ask.
Retaining wall design with a Form 15 starts from $720 + GST. Other jobs are quoted at a fixed price based on size and complexity, so you know the cost before we start.
Not always. If the area is accessible and we have permission to enter, we can inspect without you there. For leak investigations and internal inspections we will arrange a time that suits you.
Yes. We hold professional indemnity insurance. Certificates are available on request.
A Form 15 is the Queensland “Compliance certificate for building design or specification”. An RPEQ engineer signs it to confirm that a structure’s design will comply with the building rules if it is built as shown. Building certifiers rely on it when they approve work such as retaining walls, sheds, carports, patios and decks.
A Form 12 is an “Aspect inspection certificate”. After the work is built, an engineer inspects it and confirms it was built in line with the approved design. Certifiers often ask for one before they sign off the final stage.
A Form 15 covers the design: it is issued before or during approval and says the design complies. A Form 12 covers the inspection: it is issued after the work is built and says what was built matches. Many jobs need both.
Often, yes, if the structure needs building approval. Your building certifier will tell you which certificates they need. Small structures can be exempt or accepted development, depending on their size and location. If you’re not sure, send us the details and we’ll tell you what’s usually required.
Yes. This is called as-built certification. We inspect the existing structure, check its footings, framing and connections, and, if it complies, provide a Form 15 (and Form 12 where needed) for your certifier. If something doesn’t comply, we tell you what needs fixing and can design the repair.
Form 15 and Form 12 certificates from an RPEQ engineer are the standard documents Queensland certifiers rely on. We can work directly with your certifier if they have specific requirements.
The site address, photos of the structure (including footings and connections if visible), approximate dimensions, any existing plans, and your certifier’s contact details if you have one.
In Queensland, a retaining wall generally needs building approval, and usually an RPEQ engineer’s design, if any of these apply:
A fence on top of a wall, or a wall near a street corner, can also trigger extra requirements. Councils and certifiers check the details, so send us your plans or photos and we’ll confirm what applies to your site.
Most commonly, steel post and concrete sleeper walls, which are popular for residential sites across South-East Queensland.
A site-specific design drawing showing post sizes, spacing, footing depth, sleeper type and drainage, plus a Form 15 for your certifier. Prices start from $720 + GST.
The wall height and length, photos of the site, what’s above the wall (driveway, house, slope, pool), the distance to buildings and boundaries, and any soil report if you have one.
Yes. We inspect the wall, work out the cause (common causes are poor drainage, undersized posts or extra load above the wall), and recommend a repair or replacement design.
You can’t tell reliably by looking. A wall that supports the roof, ceiling or a floor above is load-bearing, and removing it without a proper beam can cause sagging or collapse. We inspect the wall and roof space, confirm whether it is load-bearing, and design the replacement beam and supports with the certification your builder and certifier need.
Yes. We provide structural designs and Form 15 certification for small residential works, including extensions, decks, carports, patios, sheds, and beams for openings.
Yes. We regularly work from a draftsperson’s or builder’s drawings and provide the structural details and certification to go with them.
An engineer’s report that finds where water is getting in, explains the cause, and recommends a repair. Body corporates, strata managers, owners and insurers use it to fix the right problem the first time and to decide who is responsible for the repair.
Yes. We inspect balconies, podiums, roofs, planter boxes, car parks and common areas, and provide clear reports and repair specifications that committees can act on.
We design waterproofing systems for balconies, podiums, roofs, planters, car parks and pool surrounds, and inspect work during and after installation.
Spalling happens when the steel inside concrete rusts and expands, cracking and pushing off the concrete in front of it. It is common on balconies, car parks and buildings near the coast. Left alone, it gets worse and can weaken the structure. We assess the damage and specify the repair.
Many cracks are cosmetic shrinkage cracks, but some point to movement, settlement or corroding steel. Send us photos with a coin or tape measure for scale. We’ll tell you whether it needs an inspection.
It is the design of bracing and fixings so that mechanical, electrical, hydraulic and fire services equipment (ducts, pipes, cable trays, plant) stays in place during an earthquake. In Australia, this is designed to AS 1170.4.
Mechanical, electrical, hydraulic and fire services contractors, builders and project managers on commercial and multi-residential projects where the certifier or specification requires it. We provide designs, details and certification to suit your project schedule.